Search alternatives:
a decrease » _ decreased (Expand Search), _ decreases (Expand Search)
_ decrease » _ decreased (Expand Search), _ decreases (Expand Search), _ decreasing (Expand Search)
0 decrease » _ decreased (Expand Search), _ decreases (Expand Search)
2 hz » 4 hz (Expand Search)
_ 0 » _ 10 (Expand Search), _ 30 (Expand Search), _ 20 (Expand Search)
a decrease » _ decreased (Expand Search), _ decreases (Expand Search)
_ decrease » _ decreased (Expand Search), _ decreases (Expand Search), _ decreasing (Expand Search)
0 decrease » _ decreased (Expand Search), _ decreases (Expand Search)
2 hz » 4 hz (Expand Search)
_ 0 » _ 10 (Expand Search), _ 30 (Expand Search), _ 20 (Expand Search)
-
1
Structural and magnetic properties of Ni1-xZnxFe 2O4 (x=0, 0.5 and 1) nanopowders prepared by sol-gel method
Published 2013“…The effect of composition and sintering temperature on morphology, magnetic properties, Curie temperature, specific heating rate at 295 kHz and hysteresis loss have been studied. The highest coercivity of 50 and 40 Oe, were obtained for NiFe2O 4 and Ni0.5Zn0.5Fe2O4 samples with the grain size of 35 and 29 nm, respectively. …”
Get full text
Get full text
-
2
Ferroelectric Properties and Electrocaloric Effect in Dy2O3 Substitution on Lead-Free (Na0.5 Bi0.5)0.94 Ba0.06TiO3 Ceramic
Published 2023“…Higher stability of the ferroelectric (FE) phase was obtained at room temperature for the compositions y = 0.01, 0.02 and 0.05, with optimum values for y = 0.02 as remanent polarization Pr = 32µC/cm2, as well as piezoelectric coefficients d33 = 137 pC/N, kp = 0.27 and kt = 0.16, whereas a higher content of Dy (y = 0.08) induced a remarkable decrease of the ferroelectric and piezoelectric properties. …”
Get full text
-
3
-
4
-
5
-
6
-
7
-
8
Effect of plastic deformation on Corrosion of cadmium in 0.1 m sodium Sulphate solution
Published 1993“…The results obtained indicate that the cathodic corrosion rate decreases with deformation up to 30-60% RH, depending on the surface finish. …”
Get full text
-
9
apoA2 correlates to gestational age with decreased apolipoproteins A2, C1, C3 and E in gestational diabetes.
Published 2021“…Plasma apos were measured and correlated to demographic, biochemical, and pregnancy outcome data. apoA2, apoC1, apoC3 and apoE were lower in women with GDM compared with control women (p=0.0019, p=0.0031, p=0.0002 and p=0.015, respectively). apoA1, apoB, apoD, apoH, and apoJ levels did not differ between control women and women with GDM. …”
Get full text
Get full text
-
10
Inhibitory effect of sodium nitrite on corrosion of lead in 0.1 M sodium hydroxide solution
Published 1988“…The effect of NaNO2 as an inhibitor for corrosion of lead in 0.1 M NaOH solution has been investigated at different temperatures using the Tafel plot technique. …”
Get full text
-
11
Effect of octylphenol polyethylene oxide on the corrosion inhibition of steel in 0.5 M H2SO4
Published 2004“…A non-ionic surfactant, octylphenol polyethylene oxide (OPPEO), was evaluated as an inhibitor for corrosion of low-carbon steel in 0.5M H 2SO4. Potentiodynamic and potentiostatic methods and scanning electron microscopy were used to study the inhibition effectiveness of the surfactant. …”
Get full text
Get full text
-
12
-
13
Radiographic assessment of endodontic mishaps in an undergraduate student clinic: a 2-year retrospective study
Published 2022“…The data was analysed using multiple logistic regression analysis (α = 0.05). Results. Engine-driven rotary instrumentation resulted in a significant decrease in the overall occurrence of instrumentation related endodontic mishaps by 40% compared to hand instrumentation (Odds Ratio = 0.59 [0.36–0.97], p = 0.04). …”
Get full text
Get full text
Get full text
-
14
-
15
Theoretical and experimental insights into the C-steel aqueous corrosion inhibition at elevated temperatures in 1.0M HCl via multi-carbonyl Gemini cationic surfactants
Published 2023“…The Tafel polarization revealed that at 0.1mM of LAPG and MAPG, the corrosion current density (i corr) of CS was reduced to the lowest extent (75.56 and 53.82μAcm-2) compared to 529.3μAcm-2 in the absence of the inhibitors. …”
Get full text
Get full text
Get full text
-
16
Complex-impedance response of an Ag/TeO2-V2O5/Ag structure
Published 2009“…The dielectric and complex-impedance response of the structure measured is discussed. The relaxation time τ0 was found to decrease with increasing temperature. …”
Get full text
Get full text
-
17
Pulpal blood flow changes and pain scores related to using superelastic 0.018-inch nickel titanium as the first orthodontic alignment archwire: A prospective clinical trial
Published 2021“…Patients were assigned into one of two groups based on archwire sizes used. Group 1: 0.014-inch and 0.018-inch NiTi (Six males, 14 females aged 19.4±1.33 years) and Group 2: 0.016-inch and 0.018-inch NiTi (Seven males, 13 females aged 19.6±1.45 years). …”
Get full text
Get full text
Get full text
-
18
-
19
-
20