Showing 241 - 250 results of 250 for search '(( a ((meer decrease) OR (linear decrease)) ) OR ( a ((greater decrease) OR (larger decrease)) ))', query time: 0.22s Refine Results
  1. 241

    Monovalent Anion Interaction on the Electron Flow of Photosystem II in Soyabean Cells by El Shintinawy, Fatma [فاطمة على الشنتناوي]

    Published 1994
    “…Increasing the incubation time up to 3 hours decreased the restoration to 43%. Thus, exposing the cells to N2 gas in the absence of the inhibitory anions caused an irreversible damage of photosystem II reflected by the linear electron transport from H2O to DMQ. …”
    Get full text
  2. 242

    Trends and levels of the global, regional, and national burden of appendicitis between 1990 and 2021: findings from the Global Burden of Disease Study 2021 by Letourneau, Ian D

    Published 2024
    “…Although the global age-standardised incidence rate of appendicitis has steadily decreased between 1990 and 2021, almost half of GBD regions saw an increase of greater than 10% in their age-standardised incidence rates. …”
    Get full text
    Get full text
    Get full text
  3. 243

    Trends and levels of the global, regional, and national burden of appendicitis between 1990 and 2021: findings from the Global Burden of Disease Study 2021 by Letourneau, Ian D

    Published 2024
    “…Although the global age-standardised incidence rate of appendicitis has steadily decreased between 1990 and 2021, almost half of GBD regions saw an increase of greater than 10% in their age-standardised incidence rates. …”
    Get full text
    Get full text
    Get full text
    article
  4. 244

    Effect of the length of silicon nano-dot/wire on band gap by Hassan, Walid M.I.

    Published 2014
    “…We will report on the role of the length of silicon nanowire (SNW) in determining the band gap of a structure. We find that the band gap decreases with SNW length for the same diameter and approaches the band gap for an ideal infinitely long SNW. …”
    Get full text
    Get full text
    Get full text
  5. 245

    Local supersaturation and the growth of protective scales during CO2 corrosion of steel: Effect of pH and solution flow by Sk, Mobbassar Hassan

    Published 2017
    “…We show that siderite is the first crystalline product and that chukanovite follows, with a delay time that decreases with increasing pH. …”
    Get full text
    Get full text
  6. 246

    Heat Transfer Attributes of Gold–Silver–Blood Hybrid Nanomaterial Flow in an EMHD Peristaltic Channel with Activation Energy by Souayeh, Basma

    Published 2022
    “…The equations governing this motion were simplified under the approximations of a low Reynolds number (LRN), a long wavelength (LWL) and Debye–Hückel linearization (DHL). …”
    Get full text
    Get full text
    Get full text
  7. 247

    Combined influence of temperature and flow rate of feeds on the performance of forward osmosis by Hawari, Alaa H.

    Published 2016
    “…It was also found that when increasing the draw solution (DS) temperature from 20 °C to 26 °C the flux increased linearly and then started decreasing when temperature increased over 26 °C due to the development of a temperature gradient. …”
    Get full text
    Get full text
  8. 248
  9. 249

    Effect of surfactant and electron treatment on the electrical and thermal conductivity as well as thermal and mechanical properties of ehylene vinyl acetate/expanded graphite compo... by Sefadi, Jeremia Shale

    Published 2015
    “…The thermal conductivity linearly increased with EG content, and this increase was more pronounced in the case of SDS-EG, but decreased after EB irradiation. …”
    Get full text
    Get full text
  10. 250

    Bromate reduction by ultraviolet light irradiation using medium pressure lamp by Bensalah, Nasr

    Published 2013
    “…Increasing the UV light intensity resulted in the increase of the rate of bromate destruction. The kobs increased linearly with increasing light intensity. A UV dose of 1000 mJ/cm2 was sufficient to reduce the bromate concentration to less than 10 μg/L within 10 min. …”
    Get full text
    Get full text
    Get full text