Showing 21 - 40 results of 455 for search '(( greater increase ) OR ((( air decrease ) OR ((( did decrease ) OR ( peak decrease ))))))*', query time: 0.12s Refine Results
  1. 21

    Do high energy-efficient buildings increase overheating risk in cold climates? Causes and mitigation measures required under recent and future climates by Mutasim Baba, Fuad

    Published 2022
    “…While without adequate ventilation, the overheating risk in high-energy-efficient buildings can be higher than old buildings, where decreasing wall and window U-values and infiltration rate has a greater contribution to the increase of indoor temperature, while decreasing window SHGC has a lower contribution to the decrease in indoor temperature compared to the case with adequate ventilation. …”
    Get full text
    Get full text
    Get full text
  2. 22

    Assessment of High-resolution Local Emissions and Land-use in Air Quality Forecasting at an Urban, Coastal, Desert Environment by Christos Fountoukis (4722963)

    Published 2022
    “…The use of the local emissions allowed for a significant improvement in the representation of air quality levels in the city. The overall forecast error decreased from –51% to 8% for PM2.5 and from –88% to 20% for NOx while a significant improvement was observed in the diurnal profile of predicted ozone. …”
  3. 23
  4. 24

    Life cycle assessment of compressed air, vanadium redox flow battery, and molten salt systems for renewable energy storage by Manal AlShafi (14778373)

    Published 2021
    “…The global warming potentials of compressed air and vanadium redox flow battery decrease by 0.599 and 0.420 kg CO<sub>2</sub> eq,/kWh, respectively in case photovoltaic electricity is stored instead of grid electricity. …”
  5. 25

    Global, regional, and national burden of household air pollution, 1990–2021: a systematic analysis for the Global Burden of Disease Study 2021 by Fiona B, Bennitt

    Published 2025
    “…BackgroundDespite a substantial reduction in the use of solid fuels for cooking worldwide, exposure to household air pollution (HAP) remains a leading global risk factor, contributing considerably to the burden of disease. …”
    Get full text
    Get full text
    Get full text
    article
  6. 26

    A Multidecadal Assessment of Haze Development and Fluctuations in Visibility for Arabian Peninsula by Luqman Atique (16036586)

    Published 2024
    “…The UAE data shows strong seasonal spikes in visibility, with peaks of about 2 km. IRQ air quality was severely misty on days when visibility was approximately 0.4 km. …”
  7. 27
  8. 28
  9. 29
  10. 30

    The global, regional, and national burden of oesophageal cancer and its attributable risk factors in 195 countries and territories, 1990–2017: a systematic analysis for the Global... by Farin Kamangar (63964)

    Published 2020
    “…Countries with a low SDI and HAQ Index and high levels of indoor air pollution had a higher proportion of oesophageal squamous cell carcinoma to all oesophageal cancer cases than did countries with a high SDI and HAQ Index and with low levels of indoor air pollution. …”
  11. 31

    Urban Geometry: The Effect of Height Diversity and Buildings Configuration on Thermal Performance and Cooling Load at Urban Scale. A Case Study in Dubai / UAE by SHAREEF, SUNDUS LUAY

    Published 2018
    “…Furthermore, building orientation plays a significant role in the thermal performance of the urban block, and it contributes to the total cooling load energy saving of the urban block by 6.6 % at the peak time of cooling demand. Moreover, the research found that the variation in building heights will increase the wind velocity by up to 23 %, and this improvement in air flow affects the outdoor air temperature positively. …”
    Get full text
  12. 32

    Visitors off the trail: Impacts on the dominant plant, bryophyte and lichen species in alpine heath vegetation in sub-arctic Sweden by Monika, Rawat

    Published 2021
    “…With a greater decrease in taller forbs and shrubs than in graminoids and prostrate plants, a greater decrease in lichen than in bryophyte species, and a change in vegetation composition. …”
    Get full text
    Get full text
    Get full text
    article
  13. 33
  14. 34

    Performance comparison of different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers by Ali Pakari (14158902)

    Published 2022
    “…The results showed that the best performance, in terms of the supply air humidity ratio and enthalpy decrease, was obtained when the supply air was in counter-flow with the exhaust air, liquid desiccant, and water. …”
  15. 35

    Thermodynamic analysis of a new renewable energy based hybrid system for hydrogen liquefaction by Ratlamwala, Tahir Abdul Hussain

    Published 2012
    “…It is found that when mass flow rate of air increases the energetic and exergetic COPs decrease in an exponential form from 2.6 to 1.9, and 0.4 to 0.3, respectively. …”
    Get full text
    article
  16. 36

    An improved non-dimensional model of wet-cooling towers by QURESHI, BILAL AHMED

    Published 2020
    “…The first method shows a maximum decrease of 4.4 per cent in error, whereas in the second method, the maximum error was found to be 3.3 and 6.8 per cent when the inlet air was unsaturated and saturated, respectively. …”
    Get full text
    article
  17. 37

    Effect of the stretch rate during uniaxial testing on the mechanical properties of prolene by Ammouri, A.H.

    Published 2017
    “…Statistically significant findings suggest an increasing trend for Prolene® stiffness vs. stretch rate (R2 = 0.9679; two-tailed p value = 0.0025) where the stiffness increases 26.2% when increasing the displacement rate from 1 to 500 mm/min. For extension (%) at peak load, a decreasing trend was found vs. stretch rate (R2 = 0.81; two-tailed p value = 0.037) where increasing the displacement rate from 1 mm/min to 500 mm/min corresponds to a 22% decrease in the relative elongation of the mesh. …”
    Get full text
    Get full text
    Get full text
    Get full text
    conferenceObject
  18. 38

    The Effect of Shading Devices on the Energy Consumption of Buildings: A Study on an Office Building in Dubai by Yassine, Farah

    Published 2013
    “…One of the main sources of these emissions in the UAE is the buildings where the cooling loads required by buildings in Dubai accounts for 60% of the summer peak electricity load. Thus it is important to propose solutions to decrease energy consumptions of these buildings. …”
    Get full text
  19. 39

    Exploring urban growth–climate change–flood risk nexus in fast growing cities by Salah Basem Ajjur (14150967)

    Published 2022
    “…Surveying showed that, between 1984 and 2020, urban areas grew by 777%, and bare lands decreased by 54.7%. In addition, Doha witnessed various climatic changes with a notable increase in air temperature (+ 8.7%), a decrease in surface wind speed (− 19.5%), and a decrease in potential evapotranspiration losses (− 33.5%). …”
  20. 40

    Photocatalytic UV degradation of 2,3,7,8-tetrachlorodibenzofuran in the presence of silver zeolite by Samara, Fatin

    Published 2017
    “…The results showed that in the absence of a catalyst, degradation under 254-nm UV light resulted in changes to the peak intensity as well as energy, while the 302-nm profile showed only loss in peak intensity. …”
    Get full text
    article