-
21
-
22
Effect of sintering temperature of NBT–6BT lead-free ceramics on the structural, ferroelectric and piezoelectric properties
Published 2022“…The lead-free Na 0.5 Bi 0.5 0.94 Ba 0.06 TiO 3 (NBT-6BT) ceramics was fabricated at various sintering temperatures using a conventional solid-state reaction method. …”
Get full text
-
23
Ferroelectric Properties and Electrocaloric Effect in Dy2O3 Substitution on Lead-Free (Na0.5 Bi0.5)0.94 Ba0.06TiO3 Ceramic
Published 2023“…We report the impact of dysprosium (Dy, with y = 0.01, 0.02, 0.05 and 0.08) substitution in (Na0.5 Bi0.5)0.94 Ba0.06TiO3 (NBT-6BT) lead-free ceramics. The structural, vibrational dielectric, ferroelectric and electrocaloric (EC) properties of all samples were systematically investigated. …”
Get full text
-
24
Dynamic Properties of Water Confined in Graphene-Based Membrane: A Classical Molecular Dynamics Simulation Study
Published 2019“…The free energy profile of penetration revealed that the optimum interlayer distance for desalination is ~10 Å, where the minimum distance for water penetration is 7 Å. …”
-
25
Do high energy-efficient buildings increase overheating risk in cold climates? Causes and mitigation measures required under recent and future climates
Published 2022“…While without adequate ventilation, the overheating risk in high-energy-efficient buildings can be higher than old buildings, where decreasing wall and window U-values and infiltration rate has a greater contribution to the increase of indoor temperature, while decreasing window SHGC has a lower contribution to the decrease in indoor temperature compared to the case with adequate ventilation. …”
Get full text
Get full text
Get full text
-
26
Assessment of High-resolution Local Emissions and Land-use in Air Quality Forecasting at an Urban, Coastal, Desert Environment
Published 2022“…The use of the local emissions allowed for a significant improvement in the representation of air quality levels in the city. The overall forecast error decreased from –51% to 8% for PM2.5 and from –88% to 20% for NOx while a significant improvement was observed in the diurnal profile of predicted ozone. …”
-
27
-
28
Life cycle assessment of compressed air, vanadium redox flow battery, and molten salt systems for renewable energy storage
Published 2021“…The global warming potentials of compressed air and vanadium redox flow battery decrease by 0.599 and 0.420 kg CO<sub>2</sub> eq,/kWh, respectively in case photovoltaic electricity is stored instead of grid electricity. …”
-
29
-
30
Global, regional, and national burden of household air pollution, 1990–2021: a systematic analysis for the Global Burden of Disease Study 2021
Published 2025“…BackgroundDespite a substantial reduction in the use of solid fuels for cooking worldwide, exposure to household air pollution (HAP) remains a leading global risk factor, contributing considerably to the burden of disease. …”
Get full text
Get full text
Get full text
article -
31
A Multidecadal Assessment of Haze Development and Fluctuations in Visibility for Arabian Peninsula
Published 2024“…The UAE data shows strong seasonal spikes in visibility, with peaks of about 2 km. IRQ air quality was severely misty on days when visibility was approximately 0.4 km. …”
-
32
-
33
-
34
Analysis of Innovative Vapor Compression and Thermal Energy Storage Systems Using Alternative Refrigerants
Published 2016Get full text
doctoralThesis -
35
Thermo-Economic Evaluation of Maisotsenko-Desiccant Cooling Systems for Gas Turbine Power Plants
Published 2018Get full text
doctoralThesis -
36
The global, regional, and national burden of oesophageal cancer and its attributable risk factors in 195 countries and territories, 1990–2017: a systematic analysis for the Global...
Published 2020“…Between 1990 and 2017, age-standardised incidence decreased by 22·0% (18·6–25·2), mortality decreased by 29·0% (25·8–32·0), and DALYs decreased by 33·4% (30·4–36·1) globally. …”
-
37
Urban Geometry: The Effect of Height Diversity and Buildings Configuration on Thermal Performance and Cooling Load at Urban Scale. A Case Study in Dubai / UAE
Published 2018“…Furthermore, building orientation plays a significant role in the thermal performance of the urban block, and it contributes to the total cooling load energy saving of the urban block by 6.6 % at the peak time of cooling demand. Moreover, the research found that the variation in building heights will increase the wind velocity by up to 23 %, and this improvement in air flow affects the outdoor air temperature positively. …”
Get full text
-
38
Performance comparison of different flow arrangements of 4-fluid internally-cooled liquid desiccant dehumidifiers
Published 2022“…The results showed that the best performance, in terms of the supply air humidity ratio and enthalpy decrease, was obtained when the supply air was in counter-flow with the exhaust air, liquid desiccant, and water. …”
-
39
Evidence-based safety education and training for traffic injury prevention
Published 2015“…Bicycle skill training for children and youth may increase their safety knowledge, but not necessarily improve their behavior or decrease their injury rates. …”
-
40
Thermodynamic analysis of a new renewable energy based hybrid system for hydrogen liquefaction
Published 2012“…It is found that when mass flow rate of air increases the energetic and exergetic COPs decrease in an exponential form from 2.6 to 1.9, and 0.4 to 0.3, respectively. …”
Get full text
article