Showing 4,261 - 4,280 results of 18,439 for search 'significantly ((((((less decrease) OR (largest decrease))) OR (mean decrease))) OR (a decrease))', query time: 0.64s Refine Results
  1. 4261
  2. 4262
  3. 4263
  4. 4264
  5. 4265

    All data from the experiment. by Kazufumi Hisamoto (21416905)

    Published 2025
    “…Therefore, we aimed to investigate whether mild hyperbaric hyperoxia enhances aerobic capacity and decreases cardiopulmonary stress during exercise with a particular focus on the ventilatory threshold (VT). …”
  6. 4266
  7. 4267
  8. 4268
  9. 4269

    The protocol of the maximal cycle-ergometer test. by Kazufumi Hisamoto (21416905)

    Published 2025
    “…Therefore, we aimed to investigate whether mild hyperbaric hyperoxia enhances aerobic capacity and decreases cardiopulmonary stress during exercise with a particular focus on the ventilatory threshold (VT). …”
  10. 4270
  11. 4271
  12. 4272
  13. 4273

    Impact of sludge dosage on HPST. by Peng Zhao (128233)

    Published 2025
    “…The model optimization and experimental validation showed that the optimal HPST conditions for treating domestic sewage were as follows: the dosage of polyaluminum chloride (PAC) was 1.70 g/L, cationic polyacrylamide (CPAM) dosage was 2.35 mg/L, sewage pH was maintained at 8.0, sludge dosage was 10 mL/L, stirring time lasted for 5 minutes, and settling time lasted for 30 minutes. As a result of these optimized conditions, the turbidity of treated sewage decreased to 1.19 NTU.…”
  14. 4274

    Impact of settling time on HPST. by Peng Zhao (128233)

    Published 2025
    “…The model optimization and experimental validation showed that the optimal HPST conditions for treating domestic sewage were as follows: the dosage of polyaluminum chloride (PAC) was 1.70 g/L, cationic polyacrylamide (CPAM) dosage was 2.35 mg/L, sewage pH was maintained at 8.0, sludge dosage was 10 mL/L, stirring time lasted for 5 minutes, and settling time lasted for 30 minutes. As a result of these optimized conditions, the turbidity of treated sewage decreased to 1.19 NTU.…”
  15. 4275

    ANOVAs for the response surface of Eq (2). by Peng Zhao (128233)

    Published 2025
    “…The model optimization and experimental validation showed that the optimal HPST conditions for treating domestic sewage were as follows: the dosage of polyaluminum chloride (PAC) was 1.70 g/L, cationic polyacrylamide (CPAM) dosage was 2.35 mg/L, sewage pH was maintained at 8.0, sludge dosage was 10 mL/L, stirring time lasted for 5 minutes, and settling time lasted for 30 minutes. As a result of these optimized conditions, the turbidity of treated sewage decreased to 1.19 NTU.…”
  16. 4276

    Impact of CPAM dosage on HPST. by Peng Zhao (128233)

    Published 2025
    “…The model optimization and experimental validation showed that the optimal HPST conditions for treating domestic sewage were as follows: the dosage of polyaluminum chloride (PAC) was 1.70 g/L, cationic polyacrylamide (CPAM) dosage was 2.35 mg/L, sewage pH was maintained at 8.0, sludge dosage was 10 mL/L, stirring time lasted for 5 minutes, and settling time lasted for 30 minutes. As a result of these optimized conditions, the turbidity of treated sewage decreased to 1.19 NTU.…”
  17. 4277

    Impact of sewage pH on HPST. by Peng Zhao (128233)

    Published 2025
    “…The model optimization and experimental validation showed that the optimal HPST conditions for treating domestic sewage were as follows: the dosage of polyaluminum chloride (PAC) was 1.70 g/L, cationic polyacrylamide (CPAM) dosage was 2.35 mg/L, sewage pH was maintained at 8.0, sludge dosage was 10 mL/L, stirring time lasted for 5 minutes, and settling time lasted for 30 minutes. As a result of these optimized conditions, the turbidity of treated sewage decreased to 1.19 NTU.…”
  18. 4278

    Impact of PAC dosage on HPST. by Peng Zhao (128233)

    Published 2025
    “…The model optimization and experimental validation showed that the optimal HPST conditions for treating domestic sewage were as follows: the dosage of polyaluminum chloride (PAC) was 1.70 g/L, cationic polyacrylamide (CPAM) dosage was 2.35 mg/L, sewage pH was maintained at 8.0, sludge dosage was 10 mL/L, stirring time lasted for 5 minutes, and settling time lasted for 30 minutes. As a result of these optimized conditions, the turbidity of treated sewage decreased to 1.19 NTU.…”
  19. 4279
  20. 4280